TherOzone T-1000 Directions SUMMARY OF OPERATIONS TherOzone Safety Information T-1000's Time Clock Notice: Failure to follow these recommended steps or directions for your TherOzone machine may void your warranty. 1. It is extremely
important that you do not
overfill the water bottles with water *, see fill line instructions
below.
2. Never transport the T-1000 unit with the water bottle attached. Do not store the T-1000 unit on its side with the water bottle attached, especially if the bottle has water in it. |
|||
|
* WATER BOTTLE "MAXIMUM FILL LINE"
![]() |
* WATER BOTTLE "MAXIMUM FILL LINE"
(close-up)
![]() |
||
|
STEP ONE
![]() |
STEP
TWO: (Connecting Bottle)
![]() |
![]() |
|
|
Caution:
Before plugging unit into
wall outlet, first place plug into back of T-1000 TherOzone unit. Then
place the plug into the outlet and turn switch on (on back of unit).
|
Fill
bottle with DISTILLED WATER ONLY
(2-4°C or 36-38°F), just below the maximum fill line, and then place tube
through hole in top of the bottle. Fill to below the
neck or top of therozone sticker. Do not fill above TherOzone logo on bottle!
|
||
|
STEP
THREE: (Connecting Bottle)
![]() |
STEP
FOUR: (Connecting Bottle)
![]() |
![]() |
|
|
Lift
bottle up towards the securing coupler.
|
Position
bottle up towards the securing coupler securing coupler with upward
pressure until it clicks into place.
|
||
|
STEP
FIVE: (Connecting Bottle)
![]() |
STEP
SIX: (Connecting Bottle)
![]() |
||
|
Stabilize
top of unit while lifting from bottom of bottle to secure properly.
|
For
the unit to function properly the bottle must be connected securely.
|
||
|
STEP
SEVEN: (Start Ozonation)
![]() |
![]() |
STEP
EIGHT: (Process is Complete)
![]() |
![]() |
|
Press
the START button to begin the unit's function.
|
After
approximately 5 minutes, 15 seconds the process will be complete.
|
||
|
STEP
NINE: (Removing Bottle)
![]() |
STEP
TEN: (Removing Bottle)
![]() |
||
|
To
remove bottle squeeze fingers between bottle coupler while stabilizing
the bottom of the bottle.
|
As
coupler releases gently detach bottle from the unit while stabilizing
the bottom of the bottle. Expect some gas release.
|
||
|
STEP ELEVEN:
(Removing Bottle)
![]() |
GREEN: Power light, unit is plugged in and the switch is on. YELLOW: Bottle is in place, coupler is correct, and start button is pressed. BLUE: Cycle is complete and water is ozonated. RED: Light is Off - bottle is in place Light is On - bottle is
not in
place.
Flashing
Red Light
-
pressure in system has dropped. (See following
summary of operations) |
![]() |
|
|
Continue to remove
bottle by gently lifting it away from the tube.
|
|||
SUMMARY OF OPERATIONS • TherOzone
T-1000 unit is plugged in, on switch is pressed, green and red light
are on.
• Bottle is filled below the Maximum Fill Line with distilled water (2-4°C or 36-38°F), coupler is connected, green light is on, and red light is off. Do not fill above TherOzone logo on bottle! • Press start button, yellow and green light are now on. • Cycle will complete in 5 minutes, 15 seconds, green and blue light are on. • To restart cycle, if bottle is left in place, press reset button, then start button, and cycle will re-run for 5 minutes. • You may stop cycle by disconnecting the bottle (see Step #9) or by pressing the reset button. • If the red reset light is flashing the system has lost pressure, remove bottle (see Step #9) and reconnect couplers (see Step #5), and then press start again. • For further questions please see contact information below and be sure to follow step by step Directions for Use of T-1000 Unit. • To test if your T-1000 unit is optimally functioning and producing aqueous ozone 3.2-4.0 ppm you will need to purchase a CHEMetrics K-7402 Tester and follow TherOzone's Directions for properly diluting and calculating aqueous ozone content. |
|||
| TherOzone,